Part Number Search Enter Part Number
Contains Exact Match


online catalog

HD30 & HDP20 SERIES

Contact Insertion


1. Grasp contact approximately (25.4 mm) one inch behind the contact crimp barrel.

2. Hold connector with rear grommet facing you.

3. Push contact straight into connector grommet until a positive stop is felt. A slight tug will confirm that it is properly locked in place.
NOTE: For unused wire cavities, insert sealing plugs for full environmental sealing

Contact Removal


1. With rear insert toward you, snap appropriate size extractor tool over the wire of contact to be removed.

2. Slide tool along into the insert cavity until it engages contact and resistance is felt.

3. Pull contact-wire assembly out of connector.
NOTE: Do not twist or insert tool at an angle


Did You Know?

Deutsch has a common contact system.

Connector Selector


Customer Spotlight

Sure Power
Read more about Sure Power
Add your products to our customer spotlight ยป