Contact Insertion
Grasp crimped contact approximately (25.2 mm) one inch behind the contact barrel. dt_1
Hold connector with rear grommet facing you. dt_2
Push contact straight into connector grommet until a click is felt. A slight tug will confirm that it is properly locked in place. dt_3
Once all contacts are in place, insert orange wedge will arrow pointing toward exterior locking mechanism. The orange wedge will snap into place. Rectangular wedges are not oriented. They may go in either way.
NOTE: The receptacle is shown - use the same procedure for plug
dt_4
Contact Removal
Remove orange wedge using needlenose pliers or a hook shaped wire to pull wedge straight out. dt_5
To remove the contacts, gently pull wire backwards, while at the same time releasing the locking finger by moving it away from the contact with a screwdriver. dt_6